Step | | Procedure & Parts & Tools |
1 |
|
REMOVE THE 4 SCREWS HOLDING THE HANDLE.
Screwdriver-phillips |
|
|
2 |
|
LIFT THE HANDLE UP.
|
3 |
|
DISCONNECT THE PLUG AND REMOVE THE HANDLE FROM THE MACHINE.
|
4 |
|
FLIP THE PUMP WIRE COVER DOWN TO OPEN IT.
|
5 |
|
PULL THE WHITE WIRE CONNECTOR FROM THE PUMP AND THE BLACK WIRE CONNECTOR FROM THE SWITCH. RECONNECT THE WHITE PLUG FROM STEP 3. INSERT VOLT METER LEADS INTO THE BLACK AND WHITE WIRE CONNECTORS. PLUG THE MACHINE IN AND TURN IT ON. SET THE VOLT METER TO VOLTAGE. THE VOLT METER SHOULD READ APPROX. 120 VOLTS.
Volt meter (True RMS capable) |
|
|
6 |
|
IF THE SWITCH AND PUMP IS OKAY, REVERSE STEPS 1 THRU 5 TO REASSEMBLE THE MACHINE.
|